Bereiche | Tage | Auswahl | Suche | Downloads | Hilfe
HK: Physik der Hadronen und Kerne
HK 48: Instrumentation and Applications VI
HK 48.5: Vortrag
Donnerstag, 14. März 2002, 17:15–17:30, F
Charged Particle Detection with PbWO4 — •Matthias Hoek1, Werner Döring1, Volker Hejny2, Herbert Löhner3, Volker Metag1, Rainer Novotny1, and Heinrich Wörtche3 — 1II. Physikalisches Institut, Universität Giessen, Germany — 2Institut für Kernphysik, FZ-Jülich, Germany — 3Kernfysich Versneller Instituut, Groningen, The Netherlands
The response of PbWO4 to high energy charged hadrons has been investigated in two test experiments at the proton beam facilities COSY, FZ-Jülich (E=1.2 GeV) and AGOR, KVI, Groningen (E=85MeV). For the first time, the energy resolution for protons and deuterons below 360 MeV energy, which were stopped within 150 mm of PbWO4, has been determined to σ/E=0.97%/√E + 3.33%. The result is comparable to the previously deduced photon response. Energy spectra of inelastically scattered protons below 85MeV measured with pure and doped PbWO4-crystals are compared to similar distributions obtained for BaF2- and CeF3-detectors. The comparison to the response of charged pions indicates a strong quenching factor (>3) of the scintillation light for hydrogen isotopes. The obtained results document the applicability of PbWO4 in photon and particle detection at medium energies.