Test Stand of the RFQ-Drifttube-Combination for the Therapy Center in Heidelberg — •Manuela Otto, Alexander Bechtold, and Alwin Schempp — IAP Johann-Wolfgang-Goethe Universitaet Frankfurt
A beam test stand for the Heidelberg medicine RFQ is under construction at the IAP in Frankfurt. The installation consists of a 8 keV/u H+ duoplasmatron ion source, the 400 keV/u RFQ itself and several diagnostic elements comprising a slit-grid emittance measurement system for scanning the transverse beam profile and a bending magnet for measuring the longitudinal beam properties. The test installation will be described in detail, first measurements will be presented.