DPG Phi
Verhandlungen
Verhandlungen
DPG

Frankfurt 2006 – wissenschaftliches Programm

Bereiche | Tage | Auswahl | Suche | Downloads | Hilfe

MS: Massenspektrometrie

MS 5: Präzisions-MS kurzlebiger Nuklide 1

MS 5.6: Vortrag

Mittwoch, 15. März 2006, 15:30–15:45, H1

Non-destructive detection of image currents for high-accuracy mass measurements of short-lived nuclides — •Jens Ketelaer1, Klaus Blaum1,2, Michael Block2, Rafael Ferrer1, Stefan Stahl3, Christine Weber1,2, and the SHIPTRAP collaboration21Institut für Physik, Johannes Gutenberg-Universität Mainz, 55099 Mainz, Germany — 2GSI Darmstadt, 64291 Darmstadt, Germany — 3Stahl-Electronics, 67582 Mettenheim, Germany

To perform high-accuracy mass measurements on some rarely produced nuclides heavier than uranium, ions of the species will be stored in a Penning trap. While moving in the trap, the ions induce an image current e.g. in the segmented ring electrode. The frequency is directly related to the charge-to-mass ratio of the nuclide of interest.

For SHIPTRAP, a new cryogenic Penning trap setup has been built [1]. This consists of a cylindrical purification trap, a hyperbolically shaped measurement trap - both at 77 K - and a superconducting coil at 4 K.

The coil and parasitary capacitances form a resonance circuit, which has to match the frequency of the ion motion. This technique is needed to determine the weak image current induced by a singly charged ion.

First tests of the characteristics of the superconducting coil and the attached electronics will be done in an off-line setup, providing similar conditions as far as temperature and pressure are concerned. The current status will be presented.

[1] C. Weber et al., Eur. Phys. J. A 25, S01, 65 (2005)