Düsseldorf 2007 – wissenschaftliches Programm
Bereiche | Tage | Auswahl | Suche | Downloads | Hilfe
A: Fachverband Atomphysik
A 25: Poster II - Photoionization
A 25.3: Poster
Donnerstag, 22. März 2007, 16:30–18:30, Poster B
Readout of Delayline Detectors using Transient Recorder Technique — •Lutz Foucar1, Achim Czasch1,2, Ottmar Jagutzki1,2, Sven Schößler1, Till Jahnke1, Horst Schmidt-Böcking1,2, and Reinhard Dörner1 — 1Johann Wolfgang Goethe-Universität Frankfurt am Main, Institut für Kernphysik — 2RoentDek GmbH, Im Vogelshaag 8, Kelkheim
In order to study high correlated systems, it is necessary to detect and measure the position of all participating fragments with high precision. To detect the position of the impact a Delayline Anode is used. Usually the readout of the Delayline Anode is done via a Constant Fraction Discriminator. We are studiing the advanced of using a Transient Recorder Readout of Delayline Anode Detektors over Constant Fraction Discriminators. Using the Transient Recorder Readout Technique, one is able to detect many particles with a very small deadtime. In this Presentation we compare the two techniques on exemplary experiments.