Bereiche | Tage | Auswahl | Suche | Downloads | Hilfe
TT: Fachverband Tiefe Temperaturen
TT 7: Matter at Low Temperature: Poster Session
TT 7.4: Poster
Montag, 25. Februar 2008, 14:00–18:00, Poster B
Mechanical loss mechanisms in crystalline quartz — •Daniel Heinert1, Anja Schroeter1, Christian Schwarz1, Ronny Nawrodt1, Ralf Neubert1, Matthias Thürk1, Wolfgang Vodel1, Andreas Tünnermann2, and Paul Seidel1 — 1Institut für Festkörperphysik, Helmholtzweg 5, D-07743 Jena, Germany — 2Institut für Angewandte Physik, Albert-Einstein-Straße 15, D-07745 Jena, Germany
Crystalline quartz is an excellent material to study internal dissipation mechanisms. Low loss materials are in great demand for future gravitational wave detectors reducing their thermal noise level within the detection band. Therefore, a deeper understanding of the loss mechanisms is necessary which depend on different parameters like the crystal orientation or the concentration of impurities. We present a detailed investigation of crystalline quartz samples ( 45 mm × 50 mm) at temperatures between 5 and 300 K. Two different crystal orientations (x-cut and z-cut) are compared. The influence of the impurities on the mechanical losses is discussed.
This work is supported by the German science foundation under contract SFB Transregio 7.