A differential MRPC prototype for CBM — •Ingo Deppner and Norbert Herrmann — Physikalisches Institut, Universität Heidelberg
The key element providing hadron identification at incident energies between 2
and 45 AGeV in the future Compressed Baryonic Matter (CBM) spectrometer at
FAIR is a time-of-flight wall placed at 10 m distance from the target covering
the polar angular range from 2.5∘-25∘ and full azimuth [1]. A
full system ToF resolution better then 80 ps is required to achieve the
necessary particle identification properties.
The existing conceptual design foresees a 120 m2 big ToF-wall composed of
Multi-gap Resistive Plate Chambers (MRPC) at which the outer-most part can be
covered with float glass RPCs in a multi-strip configuration.
Based on in-beam tests at GSI at Darmstadt and COSY at Jülich we will
present results on the performance reached with a fully differential multi-strip
MRPC prototype with normal float glass developed at the Physikalisches
Institut at University of Heidelberg.
Supported by EU/FP7 WP2; BMBF 06HD9121I.
[1] I. Deppner et al., The CBM time-of-flight wall, doi.org/10.1016
/j.nima.2010.09.165