Bereiche | Tage | Auswahl | Suche | Aktualisierungen | Downloads | Hilfe

BE: Beschleunigerphysik

BE 8: Diagnostics and Instrumentation III

BE 8.3: Vortrag

Mittwoch, 2. April 2014, 10:00–10:15, ZEU 255

Set up of a beam diagnostic system for the S-DALINAC based on rf monitors* — •Jan Hauke Hanten, Thore Bahlo, Christoph Burandt, Maximilian Herbert, Florian Hug, Patrick Nonn, Norbert Pietralla, and Thomas Schösser — Institut für Kernphysik, TU-Darmstadt, Schlossgartenstr. 9, 64289 Darmstadt

At the superconducting electron accelerator S-DALINAC a system of rf monitors is used for beam current, phase and longitudinal dispersion measurements as well as for stabilization of the beam through feedback to the rf control system. In this work we will present the setup of a newly developed electronic read out system based on FPGA boards, which allows to perform measurements on all monitors simultanously. In addition we will present the integration in the EPICS based control system of the S-DALINAC and first results from measurements on electron beam.

*funded by the DFG through SFB 634

100% | Bildschirmansicht | English Version | Kontakt/Impressum/Datenschutz
DPG-Physik > DPG-Verhandlungen > 2014 > Dresden