The Fast Piezo-Based Frequency Tuner for sc CH-Cavities — •Michael Amberg1, 2, Kurt Aulenbacher1, Winfried Barth1, Marco Busch2, Florian Dziuba2, Holger Podlech2, and Ulrich Ratzinger2 — 1Helmholtz-Institute Mainz (HIM), Mainz, Germany — 2IAP University of Frankfurt, Frankfurt am Main, Germany
Superconducting (sc) structures have to fulfill strict mechanical requirements to assure a stable operation of a cavity. Even small mechanical disturbances caused by effects like microphonic noise, pressure fluctuations of the liquid helium bath or Lorentz force detuning can change the resonance frequency of the cavity in the range of several hundred kHz. To control the slow and fast frequency variations during operation a compact frequency tuner prototype equipped with a stepper motor and a piezo actuator has been developed at the Institute for Applied Physics (IAP) of Frankfurt University. The tuner design and the results of first mechanical tests at room temperature of the first prototype are presented.