Characterization of the SESAME-Injector — •Rachid Ramadan1, Shaukat Khan1, Erhard Huttel2, and Maher Attal21DELTA, TU Dortmund — 2SESAME, Allan (Jordan)

SESAME (Synchrotron-light for Experimental Science and Applications in the Middle East) is a third-generation Synchrotron-light-source under construction located in Jordan. In consists of a 20 MeV Microtron pre-injector, a 800 MeV Booster-synchrotron and a 2.5 GeV Storage-Ring. The Microtron and the Booster-synchrotron is the former BESSY I Injector. The Booster had been commissioned in 2014. This work describes the characterization of the Microtron and the Booster. Tune, Beta-function, Dispersion, Chromaticity and Emittance have been measured and found in sufficient agreement with the expectations.