DPG Phi
Verhandlungen
Verhandlungen
DPG

Dresden 2017 – wissenschaftliches Programm

Bereiche | Tage | Auswahl | Suche | Aktualisierungen | Downloads | Hilfe

TT: Fachverband Tiefe Temperaturen

TT 54: Poster Session: Cryotechnique

TT 54.4: Poster

Mittwoch, 22. März 2017, 15:00–19:00, P2-OG3

Development of a novel calorimetry setup based on metallic paramagnetic temperature sensors — •Andreas Reifenberger, Sebastian Kempf, Andreas Fleischmann, Rüdiger Klingeler, and Christian Enss — Kirchhoff-Institut für Physik, Universität Heidelberg, INF 227, D-69120 Heidelberg

For the measurement of the specific heat of superconducting mg-sized metallic glass samples in the temperature range down to 10 mK we have developed a new microfabricated platform. It addresses challenging aspects of such a setup like the thermal contact between sample and platform, the necessary thermometer resolution and an addenda heat capacity excceeding that of the samples of interest (typically nJ/K @ 20 mK). Our novel setup is based on the relaxation method, where the thermal relaxation following a well defined heat pulse is monitored to extract the specific heat. The sample platform (5 × 5  mm2) includes a microstructured paramagnetic Ag:Er temperature sensor, which is read out by a dc-SQUID (Superconducting Quantum Interference Device) via a superconducting pickup loop. In this way, a relative temperature precision of 0.5 µ K can be reached. A gold-coated mounting area (4.4 × 3   mm2) is included to improve the thermal contact between sample and platform. The performance of our setup is presented and discussed.

100% | Mobil-Ansicht | English Version | Kontakt/Impressum/Datenschutz
DPG-Physik > DPG-Verhandlungen > 2017 > Dresden