Würzburg 2018 – scientific programme
Parts | Days | Selection | Search | Updates | Downloads | Help
AKBP: Arbeitskreis Beschleunigerphysik
AKBP 4: Diagnostics, Control and Instrumentation
AKBP 4.2: Talk
Tuesday, March 20, 2018, 16:45–17:00, NW-Bau - HS4
Cavity Beam Position Monitor development at CLEAR(CERN) — •Johannes Nadenau for the JEDI collaboration — Institut für Kernphysik, Forschungszentrum Jülich — III. Physikalisches Institut B, RWTH Aachden University
At the CERN Linear Electron Accelerator for Research (CLEAR) facility component studies for existing and future machines are performed. Part of these studies are cavity Beam Position Monitor (BPM) developments. Cavity BPMs provide high accuracy position measurements. CLEAR is equiped with three BPMs which allows to measure positions on two devices and check the predicted position in the third one. In the talk the principle of measurement and first results will be discussed.