|
16:30 |
MS 3.1 |
MOCCA: a 4k-pixel molecule camera for the position and energy resolved detection of neutral molecule fragments — •Dennis Schulz, Steffen Allgeier, Christian Enss, Andreas Fleischmann, Lisa Gamer, Loredana Gastaldo, Julia Hauer, Sebastian Kempf, Sebastian Spaniol, Oldřich Novotný, and Andreas Wolf
|
|
|
|
16:30 |
MS 3.2 |
Recent developments at the Greifswald MR-ToF device — •Paul Fischer, Gerrit Marx, and Lutz Schweikhard
|
|
|
|
16:30 |
MS 3.3 |
Photoexcitation of size-selected ions in an electrostatic storage device — •Paul Fischer, Gerrit Marx, and Lutz Schweikhard
|
|
|
|
16:30 |
MS 3.4 |
High-Precision Mass Measurements with PENTATRAP — •Rima X. Schüssler, José R. Crespo López-Urrutia, Menno Door, Pavel Filianin, Wenjia Huang, Charlotte König, Kathrin Kromer, Yuri. N. Novikov, Alexander Rischka, Christoph Schweiger, Sven Sturm, Stefan Ulmer, Sergey Eliseev, and Klaus Blaum
|
|
|
|
16:30 |
MS 3.5 |
Development of an efficient high-current ion source for Accelerator Mass Spectrometry — •Dimitar Yordanov, Hans Hofsäss, Georg Rugel, Shavkat Akhmadaliev, Johannes von Borany, and Jenny Feige
|
|
|
|
16:30 |
MS 3.6 |
Interaction of size-selected stored anionic tin clusters with electrons — •Markus Wolfram, Steffi Bandelow, Alexander Jankowski, Stephan König, Gerrit Marx, and Lutz Schweikhard
|
|
|
|
16:30 |
MS 3.7 |
The Heidelberg compact EBIT as a source for highly charged holmium ions for high-precision mass spectrometry at Pentatrap — •Ch. König, J. R. Crespo López-Urrutia, M. Door, Ch. E. Düllmann, P. Filianin, W. Huang, K. Kromer, D. Renisch, A. Rischka, R. X. Schüssler, Ch. Schweiger, S. Eliseev, and K. Blaum
|
|
|
|
16:30 |
MS 3.8 |
Environmental influences on the high-precision mass measurements at PENTATRAP — •K. Kromer, M. Door, A. Rischka, R.X. Schüssler, C. König, Ch. Schweiger, W. Huang, P. Filianin, S. Eliseev, and K. Blaum
|
|
|
|
16:30 |
MS 3.9 |
Activity determination of reference nuclides in the nuclear waste management — •C. Müller-Gatermann, S. Heinze, M. Schiffer, A. Stolz, G. Hackenberg, S. Herb, L. Bussmann, R. Spanier, A. Dewald, R. Magreiter, E. Strub, M. Michel, K. Eberhardt, M. Dewald, and B. Dittmann
|
|
|
|
16:30 |
MS 3.10 |
Investigation of formate and halide adducts on coinage metal phosphine complexes in isolation — •Björn Kwasigroch, Sebastian V. Kruppa, Michael Borchers, Christoph Riehn, and Gereon Niedner-Schatteburg
|
|
|
|
16:30 |
MS 3.11 |
The contribution has been withdrawn.
|
|
|
|
16:30 |
MS 3.12 |
A graphene-based neutral particle detector — •Jessica Warbinek, David Leimbach, Di Lu, Dag Hanstorp, David Pegg, Jakob Welander, Avgust Yurgens, and Klaus Wendt
|
|
|
|
16:30 |
MS 3.13 |
Towards parts per trillion mass measurements on light nuclei at LIONTRAP — Sascha Rau, Fabian Heiße, •Florian Köhler-Langes, Wolfgang Quint, Sven Sturm, and Klaus Blaum
|
|
|
|
16:30 |
MS 3.14 |
Metastable states of the silicon anion observed in a cryogenic storage ring — •D. Müll, F. Grussie, E. A. Guerin, A. Becker, K. Blaum, C. Breitenfeldt, S. George, J. Göck, M. Grieser, R. von Hahn, P. Herwig, J. Hörl, Á. Kálosi, J. Karthein, C. Krantz, H. Kreckel, S. Lohmann, C. Meyer, P. M. Mishra, O. Novotný, A. P. O’Connor, D. Paul, R. Repnow, S. Saurabh, K. Spruck, S. Sunil Kumar, X. Urbain, S. Vogel, P. Wilhelm, and A. Wolf
|
|
|
|
16:30 |
MS 3.15 |
Construction of a new electrospray ionization time of flight mass spectrometer (ESI-TOF-MS) for femtosecond laser experiments — •Peter Krüger and Karl-Michael Weitzel
|
|
|