Mittwoch, 13. März 2019, 11:30–11:45, U A-Esch 2

First tests of the new 135 gas-filled magnet at the Cologne 10 MV AMS-System — •Susan Herb, Richard Spanier, Markus Schiffer, Heinze Stefan, Claus Müller-Gatermann, Gereon Hackenberg, Lena Bussmann, Alexander Stolz, and Alfred Dewald — Institut für Kernphysik, Universität zu Köln

The AMS setup at the Cologne 10 MV Tandem Accelerator is dedicated to measure isotopic ratios of medium mass nuclei. After the first measurements of 53Mn, measurements of 60Fe and 63Ni are possible with the new 135 gas-filled magnet. The isotope 60Fe is of great importance for nuclear astrophysics and 63Ni for nuclear waste management. Test measurements of the new gas-filled magnet were performed with stable Fe and Ni beams. In order to avoid high energy loss in the entrance window of the magnet, the mylar-foil was replaced by a Si3N4 window. In addition a new 5-anode gas-detector was positioned after the magnet. A large 2cmx2cm Si3N4 foil is used at the entrance and x-slits allow to reduce scattered particles. We will present the first results on the isotope separation and transmission of the system.