DPG Phi
Verhandlungen
Verhandlungen
DPG

SMuK 2023 – wissenschaftliches Programm

Bereiche | Tage | Auswahl | Suche | Aktualisierungen | Downloads | Hilfe

HK: Fachverband Physik der Hadronen und Kerne

HK 74: Poster

HK 74.8: Poster

Donnerstag, 23. März 2023, 17:30–19:00, HSZ EG

Studies on Alternative Sensor Carrier Concepts for the CBM MVD* — •Fabian Hebermehl for the CBM-MVD collaboration — Goethe-Universität Frankfurt

The Micro Vertex Detector (MVD), part of the Compressed Baryonic Matter (CBM) Experiment at the future FAIR facility, comprises four detector stations, of four 0.3−0.5 %  X0 thin quadrants, respectively. As the MVD will be operating in vacuum, efficient thermal management by the carrier of the sensors is mandatory. For this reason, the carrier materials chosen are Thermal Pyrolitic Graphite (TPG) for the larger stations and pCVD diamond for the smallest, first station. Studies have been conducted on alternative concepts for the TPG stations to balance thermal performance, material budget and production yield. The station production yield is driven by the need to populate both carrier sides with large-area MIMOSIS sensors to minimize inactive areas inside the detector acceptance. The options to (i) integrate ladders rather then carrier plates and (ii) separate front and back side sensor integration have been studied. The contribution will summarize the findings and gives a recommendation of which design is best suited for refining MVD station concept accordingly.

*This work has been supported by bmbf (05P21RFFC2) and EURIZON.