DPG Phi
Verhandlungen
Verhandlungen
DPG

Gießen 2024 – wissenschaftliches Programm

Bereiche | Tage | Auswahl | Suche | Aktualisierungen | Downloads | Hilfe

HK: Fachverband Physik der Hadronen und Kerne

HK 72: Poster

HK 72.42: Poster

Donnerstag, 14. März 2024, 17:15–18:45, HBR 14: Foyer

The front-end signal path of the P2 experiment at MESASebastian Baunack1, Maarten Bonekamp2, Boris Gläser1, •Rahima Krini1, Frank Maas1,3,4, Moran Neher1, David R. Pineiro3, Tobias Rimke1, and Malte Wilfert1 for the P2 collaboration — 1Institute for Nuclear Physics, Mainz, Germany — 2IRFU, CEA, Université Paris-Saclay, Gif-sur-Yvette, France — 3Helmholtz Institute Mainz, Germany — 4PRISMA+ Cluster of Excellence, Johannes Gutenberg-Universität Mainz

The Mainz Energy recovering Superconducting Accelerator (MESA) is being built at the Institute for Nuclear Physics in Mainz. At MESA the P2 experiment is planned for a precision measurement of the weak mixing angle. The weak mixing angle sin2θW can be measured in parity violating elastic electron-proton scattering. The aim of the P2 experiment is to measure the weak mixing angle with an accuracy of 0.15% at a low four-momentum transfer of Q2=4.5·10−3GeV2.
The small asymmetries O(10−8) and the high precision require very high statistics. Therefore an integrating measurement with the associated integrating data acquisition readout chain is needed. A joint read-out electronics for P2 experiment in Mainz and for Moeller experiment at the Jefferson Laboratory is in development by collaborators of University of Manitoba. The latest prototype of a full differential integrating detector signal chain was built and tested at MAMI (Mainzer Mikrotron). The results fulfill the requirements of the P2 parity violation experiment and will be presented in this conference.

Keywords: parity violation; weak mixing angle; read-out electronics; MESA; P2

100% | Mobil-Ansicht | English Version | Kontakt/Impressum/Datenschutz
DPG-Physik > DPG-Verhandlungen > 2024 > Gießen