Münster 1999 – wissenschaftliches Programm
Bereiche | Tage | Auswahl | Suche | Downloads | Hilfe
TT: Tiefe Temperaturen
TT 9: Postersitzung I: TT-Teilchendetektoren (1-7), TT-Techniken (8-11), 2-D-Systeme (12-21), Meso- u. nanoskopische Strukturen (22-44), Niederdim. Spinsysteme (45-60), Tunneln u. Symmetrien (61-65), SQUID-Anwendungen (66-73), Massive HTSL, Bandleiter (74-96)
TT 9.7: Poster
Dienstag, 23. März 1999, 09:30–12:30, Z
The CRESST Experiment — •M. Sisti — Max-Planck-Institut f"ur Physik
The CRESST experiment is a dark matter search using high mass high resolution cryogenic detectors. In the first phase four calorimeters consisting of a 262 g sapphire absorber with a tungsten thermometer and SQUID read-out are used. These detectors are operated at about 12 mK and have a energy resolution between 150 eV and 200 eV at 1.5 keV. The present set-up, detectors, and performance are presented.